Curtis Instruments

 Preco Safety

 Printed Motor Works

Curtis 701 - Hour Meter Rectangular - 12-48vDC 701DN00101248

$ 71.50 each

20 items in stock
+

Curtis InstrumentsThe Curtis 700 Series are highly reliable solid state hour meters and counters that offer an unprecedented combination of patented technology, performance, reliability and value.

Suitable for a wide variety of industrial and commercial applications, including scheduled maintenance, warranty and leasing – for medical equipment, transport and industrial vehicles and other industrial equipment.


 

{tab=Features}

MODEL 700: 2-Wire Hour Meter, displays only when powered. Available in AC/DC.
MODEL 701: 3-Wire Hour Meter, has a provision or continuous display. Available in AC/DC and DC-only.
MODEL 703: Pulse Counter. Available in AC/DC and DC-only.

  • All-8’s LCD function test: each digit displays an eight for one second after power-up.
  • Attractive 6-digit LCD 5mm or 7mm high digits (7mm with optional backlighting) are much easier to read than
  • electromechanical meters, which have only 3mm high digits.
  • Silent operation – no moving parts. Eliminates annoying gear and motor noise.
  • Exceptional reliability due to nonvolatile memory (EEPROM) which retains data for 25+ years.
  • Wide voltage ranges, for example, one unit can be powered from 75 to 270 VAC anywhere between 48 and 440 Hz – ideal for distribution and worldwide markets without having to stock multiple model types.
  • Electrical reset (optional).
  • Available in ten case styles – all fit in standard hour meter/ counter cutouts.
  • Multiple mountings available – Metal U-bracket, “U” clamp/ stud (D, Q, R and S cases), flange mount with hardware (F, T, G, J cases), or mounting clip (G, L, Y, Z, cases).
  • Backlit units allow external illumination control, i.e., on/off or dimmer (12VDC only).
  • Flashing hourglass icon indicates when the hour meter is accumulating time.
  • Memory will arm only when power has been applied for five seconds (with no loss of time or counts).
  • Low power consumption.
  • UL and CE recognized.

{tab=Specifications}

Case Style

Bezel Shape

Lens Material

Case Material

IP Rating Front/Rear

Termination

UL5
/CE

Suggested Panel
Cutout (mm)

D

Rectangle

Acrylic

ABS

65/50

3/16” Spade

Yes

45.0 x 22.2

F/T

Hexagon

Acrylic

ABS

65/65

Spade 7

Yes

36.8 x 24.1

G

Hexagon

Acrylic

ABS

65/651

Packard (2 pin) 2

Yes

36.8 x 24.1

J

Hexagon

Acrylic

ABS

65/651

Packard (4 pin) 3

Yes

36.8 x 24.1

L

Rectangle

P'carbonate

P'carbonate

65/40

Molex 4

Yes

36.8 x 24.1

Q

Round

Glass

P'carbonate

65/506

1/4” Spade

Yes

ø52 (ø2–1/16)

R (5mm)

Round

Glass

P'carbonate

65/506

3/16” Spade

Yes

ø52 (ø2–1/16)

R (7mm)

Round

Glass

P'carbonate

65/50

1/4” Spade

Yes

ø52 (ø2–1/16)

S

Square

Glass

ABS

52/50

1/4” Spade

Yes

45.0 x 45.0

Y

Rectangle

Acrylic

ABS

65/651

Packard (4 pin) 3

Yes

36.8 x 24.1

Z

Rectangle

Acrylic

ABS

65/65

1/4” Spade

Yes

36.8 x 24.1

 

  • Display 6 digit LCD, 5 or 7mm high, 6 o’clock viewing angle
  • Range & Resolution Hour meters: 99,999.9 hours
  • Counters: 999,999 counts
  • Accuracy Hour meters: 0.1% Counters: ±1 count
  • Humidity 95%, non-condensing at 38°C Operating Temperature –40°C to +85°C (–40ºF to +185ºF) Storage Temperature –50°C to +85°C (–58ºF to +185ºF) Mechanical Shock SAE J 1378, 55g
  • Mechanical Vibration SAE J 1378, 20g
  • Operating Frequency 48 to 440 Hz (AC powered units)
  • Memory Main power must be applied for 5 seconds to arm memory (with no loss of time/counts).
  • EEPROM, data retained for 25+ years without power.
  • Current Consumption 0.5mA max. @ 5VDC (0512D models) (Power Terminals) 0.8mA max. @ 12VDC (1248D models)
  • 1.0mA max. @ 120VAC
  • 2.0mA max. @ 230VAC
  • Input Signal (DC-only) Counters (703 only): 500 Hz. max., 50% duty cycle (1ms low, min., between consecutive highs). Input Signal (AC/DC) Hour meters (701 only): Power must be applied for 0.5s, min., to accumulate time.
  • Counters (703 only): 1 Hz. max., 50% duty cycle (500ms low, min., between consecutive highs) Reset 5ms min. at operating voltage. Main power must be applied for a minimum of 250ms prior to reset signal.

NOTES:

  • Mating connector must be installed.
  • Equivalent to Delphi-Packard connector P/N 12162000 2-pin.
  • Equivalent to Delphi-Packard connector P/N 15336035 4-pin.
  • Equivalent to Molex connector P/N 43045–0412.
  • UL files AU1841 and E45175.
  • R(5mm) and Q housings also available in a 65/65 version (see model encodement).
  • F= 1/4”, T= 3/16”

{tab=Wiring Guide}

Case Style Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6

D, F, T, J,Q, R (5mm), Y & Z

V+

V–

I

R

N/A

N/A

G

V+

V–

N/A

N/A

N/A

N/A

L

V+

V–

I

N/A

N/A

N/A

R (7mm), S

V+

V–

R

I

L

N/A

V+ Operating voltage

V– Common (ground)

I Enable (Optional, use operating voltage to power this pin to record elapsed time (701) or increment count (703).)

R Reset (Optional, supply with operating voltage when unit is to be reset to 0.)

L Lighting control (Optional, 9–15VDC absolute only, regardless of operating voltage.) NC No connection

{tab=Dimensions}

Case Style D

Curtis Instruments 700 Series-d

Case Style F/T

Curtis Instruments 700 Series-D

Case Style G

Curtis Instruments 700 Series-G

Case Style J

Curtis Instruments 700 Series-J

Case Style L

Curtis Instruments 700 Series-L

Case Style Q

Curtis Instruments 700 Series-Q

Case Style R (5mm)

Curtis Instruments 700 Series-R (5mm)

Case Style R (7mm)

Curtis Instruments 700 Series-R (7mm)

Case Style Y

Curtis Instruments 700 Series-Y

Case Style Z

Curtis Instruments 700 Series-Z

{/tabs}